{ "currentVersion": 10.81, "cimVersion": "2.6.0", "id": 102, "name": "StormSewer_Manholes", "type": "Feature Layer", "parentLayer": { "id": 94, "name": "Base Layers" }, "defaultVisibility": true, "minScale": 6000, "maxScale": 0, "canScaleSymbols": false, "geometryType": "esriGeometryPoint", "description": "
DATA DICTIONARY<\/SPAN><\/P> <\/P> CONTENTS<\/SPAN><\/P> I. GENERAL<\/SPAN><\/P> \tA. PATs & AATs<\/SPAN><\/P> \tB. METADATA<\/SPAN><\/P> II. WATER<\/SPAN><\/P> \tA. POINT DATA (DATs)<\/SPAN><\/P> \tB. POINT RELATES (LNXs)<\/SPAN><\/P> \tC. LINE DATA (DATs)<\/SPAN><\/P> \tD. LINE RELATES (LNXs)<\/SPAN><\/P> III. STORM SEWER<\/SPAN><\/P> \tA. POINT DATA (DATs)<\/SPAN><\/P> \tB. POINT RELATES (LNXs)<\/SPAN><\/P> \tC. LINE DATA (DATs)<\/SPAN><\/P> \tD. LINE RELATES (LNXs)<\/SPAN><\/P> IV. SANITARY SEWER<\/SPAN><\/P> \tA. POINT DATA (DATs)<\/SPAN><\/P> \tB. POINT RELATES (LNXs)<\/SPAN><\/P> \tC. LINE DATA (DATs)<\/SPAN><\/P> \tD. LINE RELATES (LNXs)<\/SPAN><\/P> <\/P> <\/P> (GENERAL .PAT AND .AAT)<\/SPAN><\/P> Coverage\tPrimary Key<\/SPAN><\/P> Water\t\twater_pk<\/SPAN><\/P> Storm Sewer\tstmsewer_pk<\/SPAN><\/P> Sanitary Sewer\tsansewer_pk<\/SPAN><\/P> <\/P> (METADATA FOR STMSEWER, SANSEWER, AND WATER)<\/SPAN><\/P> <\/P> meta_data_fk\tis the linking item for the stmsewer_point.dat.<\/SPAN><\/P> dolr\t\tdate on asbuilt<\/SPAN><\/P> sheetof\t\tsheet number x of y<\/SPAN><\/P> hscale\t\thorizontal scale on asbuilt<\/SPAN><\/P> vscale\t\tvertical scale on asbuilt<\/SPAN><\/P> eng_firm\tengineering firm<\/SPAN><\/P> reg_engineer\tregistered engineer<\/SPAN><\/P> asbuilt-no\tasbuilt number<\/SPAN><\/P> dig_tech\tdigitizing technique<\/SPAN><\/P> dig_by\t\tdigitized by<\/SPAN><\/P> date_dig\tdate digitized<\/SPAN><\/P> data_source\tdata source<\/SPAN><\/P> map_title\tmap title<\/SPAN><\/P> <\/P> (WATER POINT DATA)<\/SPAN><\/P> About the Items in water_point.dat<\/SPAN><\/P> <\/P> water_fk\tis the linking item for the water.pat table.<\/SPAN><\/P> v_type_pk\tis the linking item to the v_type.lnx relate table.<\/SPAN><\/P> v_size\t\tvalve size in inches ** N/A or UNKNOWN records for this item are denoted with -9<\/SPAN><\/P> v_manufctr_pk\tis the linking item to the v_manufacturer.lnx relate table.<\/SPAN><\/P> h_manufctr_pk\tis the linking item to the h_manufacturer.lnx relate table.<\/SPAN><\/P> h_lsize\t\thydrant line size in inches ** N/A or UNKNOWN records for this item are denoted with -9<\/SPAN><\/P> h_rsize\t\thydrant riser size in inches ** N/A or UNKNOWN records for this item are denoted with -9<\/SPAN><\/P> m_type_pk\tis the linking item to the m_type.lnx relate table.<\/SPAN><\/P> m_size\t\tmeter size in inches ** N/A or UNKNOWN records for this item are denoted with -9<\/SPAN><\/P> abnd\t\tindicates whether feature is abandoned. Y = abandoned, N = not abandoned.<\/SPAN><\/P> meta_data_pk\tis the linking item to the water_md.lnx relate table.<\/SPAN><\/P> <\/P> <\/P> (WATER POINT RELATES)<\/SPAN><\/P> Itmes in v_type.lnx<\/SPAN><\/P> <\/P> Record V_TYPE_FK V_TYPE<\/SPAN><\/P> 1 1 TAPPING SLEEVE & VALVE<\/SPAN><\/P> 2 2 BLOW OFF<\/SPAN><\/P> 3 3 CONTROL<\/SPAN><\/P> 4 4 GATE<\/SPAN><\/P> 5 5 UNKNOWN<\/SPAN><\/P> 6 6 N/A<\/SPAN><\/P> 7 7 FLUSH<\/SPAN><\/P> 8 8 COUPLER<\/SPAN><\/P> 9 9 CHECK<\/SPAN><\/P> 10 10 GLOBE<\/SPAN><\/P> <\/SPAN><\/P> <\/P> Items in v_manufacturer.lnx<\/SPAN><\/P> <\/P> Record V_MANUFCTR_FK V_MANUFACTURE<\/SPAN><\/P> 1 1 AWWA<\/SPAN><\/P> 2 2 WALWARTH<\/SPAN><\/P> 3 3 MUELLER<\/SPAN><\/P> 4 4 RAINBIRD<\/SPAN><\/P> 5 5 N/A<\/SPAN><\/P> 6 6 UNKNOWN<\/SPAN><\/P> 7 7 BALL<\/SPAN><\/P> <\/SPAN><\/P> <\/SPAN><\/P> Items in h_manufacturer.lnx<\/SPAN><\/P> <\/P> Record H_MANUFCTR_FK H_MANUFACTURER<\/SPAN><\/P> 1 6 N/A<\/SPAN><\/P> 2 7 UNKNOWN<\/SPAN><\/P> 3 1 MUELLER<\/SPAN><\/P> <\/SPAN><\/P> <\/SPAN><\/P> Items in m_type.lnx<\/SPAN><\/P> <\/P> Record M_TYPE_FK M_TYPE<\/SPAN><\/P> 1 5 UNKNOWN<\/SPAN><\/P> 2 6 N/A<\/SPAN><\/P> 3 1 FLOW<\/SPAN><\/P> 4 2 TURBINE<\/SPAN><\/P> 5 4 2-WAY<\/SPAN><\/P> 6 3 DOUBLE<\/SPAN><\/P> <\/SPAN><\/P> <\/SPAN><\/P> (WATER LINE DATA)<\/SPAN><\/P> About Items in water_arc.dat<\/SPAN><\/P> <\/P> water_fk\tis the linking item for the water.aat table.<\/SPAN><\/P> p_mat_pk\tis the linking item to the p_mat.lnx relate table.<\/SPAN><\/P> p_size\t\tpipe diameter in inches ** N/A records for this item are denoted with -9<\/SPAN><\/P> p_depth\t\tpipe depth in feet ** N/A records for this item are denoted with -9<\/SPAN><\/P> abnd\t\tindicates whether feature is abandoned. Y = abandoned, N = not abandoned.<\/SPAN><\/P> meta_data_pk\tis the linking item to the water_md.lnx.<\/SPAN><\/P> <\/P> <\/P> (WATER LINE RELATE)<\/SPAN><\/P> Items in p_mat.lnx<\/SPAN><\/P> <\/P> Record P_MAT_FK PIPE_MATERIAL<\/SPAN><\/P> 1 1 VETRIFIED CLAY PIPE<\/SPAN><\/P> 2 2 CLASS 150 ASBESTOS-CEMENT<\/SPAN><\/P> 3 3 RANCHO<\/SPAN><\/P> 4 4 CORRUGATED GALVANIZED METAL PIPE<\/SPAN><\/P> 5 5 CORRUGATED METAL<\/SPAN><\/P> 6 6 CONCRETE<\/SPAN><\/P> 7 7 FULL COATED CORRUGATED METAL<\/SPAN><\/P> 8 8 UNKNOWN<\/SPAN><\/P> 9 9 PVC C-900 CLASS 150<\/SPAN><\/P> 10 10 PVC C-900 CLASS 200<\/SPAN><\/P> 11 11 PVC SDR-18<\/SPAN><\/P> 12 12 PVC<\/SPAN><\/P> 13 13 DUCTILE IRON PIPE<\/SPAN><\/P> 14 14 REINFORCED CONCRETE PIPE<\/SPAN><\/P> 15 15 OPEN DITCH<\/SPAN><\/P> 16 16 CCMP<\/SPAN><\/P> 17 17 STEEL<\/SPAN><\/P> 18 18 ASBESTOS-CEMENT<\/SPAN><\/P> 19 19 WROUGHT IRON<\/SPAN><\/P> 20 20 PVC C-900 SDR 21<\/SPAN><\/P> 21 21 PRECAST CONCRETE BOX<\/SPAN><\/P>